Material |
Stainless steel cast alloy integrative structure. |
Keypad |
12 alphanumeric stainless steel buttons.
Alps TACT Switch, 500,000 Cycle Operating Life.
|
Outside Handle |
Rotate freely in locked mode to prevent malicious destroy of the lock. |
Inside Handle |
Never locked to meet fire exit requirements. |
Handles |
Right Hand or Left Hand |
Unlock Way |
Access Code:
1. Software-generated 10-digit Access Code.
2. User-created 3-6 digit easy to remember Personalized Code.
3. No time-related private Master Code.
Physical Key:
Two Mechanical keys for emergency override, which cannot be duplicated.
|
Access Code Type |
For Guest:
1. Short term stay - Control stay length from one hour to 32 days, check-in/check-out time at any hour of the day.
2. Long term stay - Control stay length from 32 days to 732 days (2 years).
For Personnel:
1. Short term staff - Control employment term from one day to 32 days, daily start/end work time at any hour of the day.
2. Long term staff - Control employment term from one month to 24 months (2 years), daily start/end work time at any hour of the day.
3. One time use code - Control the external service people to access the property only one time on appointed day.
For Facility:
1. Short term use - Control use term from one day to 32 days, daily open/close time at any hour of the day.
2. Long term use - Control use term from one month to 24 months (2 years), daily open/close time at any hour of the day.
3. One time use code - Control the external service people to access the facility only one time on appointed day.
For Group:
It's used for staff only. One group Access Code to access all eRL Lock Devices which are defined in the same Group.
1. Short term staff - Control employment term from one day to 32 days, daily start/end work time at any hour of the day.
2. Long term staff - Control employment term from one month to 24 months (2 years), daily start/end work time at any hour of the day.
3. One time use code - Control the external service people to access the property only one time on appointed day.
|
User Code Capacity |
1. Software-generated 10-digit Access Code - Unlimited
2. User-created 3-6 digit easy to remember Personalized Code - 200
|
Disabled Code Capacity |
Up to 50 valid Access Codes can be disabled at the same time. |
Power |
4 Standard alkaline AA Batteries. Typically lasting 1-2 years under normal operating conditions. |
Low Power Alert |
1. When the battery voltage is below 4.4V, the visible and audible alarm will alert you each time after successfully unlocked.
2. The Remote Access Controller software will automatically remind you to replace the batteries.
|
Operation Indication |
Green LED, red LED, and buzzer. |
Internal Clock |
1. < ±5 minutes average deviation per year.
2. Backup power can keep clock running for 24 hours if the lock batteries are failure.
3. Automatic Daylight Savings Time and Leap Year correction.
|
Programming Method |
Three simple keypad commands:
1. Change the Master Code when first time to setup the lock.
2. Adjust the date/time in lock when needed.
3. Disable a valid Access Code when needed.
|
Operation Temperature |
Outdoor Part: -40ºF to 140ºF (-40ºC to 60ºC).
Indoor Part: 23ºF to 140ºF (-5ºC to 60ºC).
|
Keypad ESD Susceptibility |
Air > 15KV
Contact > 8KV
|
Weather |
Weather Resistant. |
Lock Dimensions |
3" X 5" X 7" (76mm X 127mm X 178mm) |
Weight |
4 lbs. (1.8Kg) |
Latch |
Adjustable backset from 2 3/8" to 2 3/4" (60mm to 70mm) with1/2" (13mm) throw. |
Door Thickness |
Fits doors 1 3/8" to 1 3/4" (34mm to 45mm) thick. |
What Included

|
1. 2-3/8" and 2-3/4" latches
2. Latch strike plate
3. Latch strike lining box
4.
Inside and outside rubber gaskets
4. Spanner
5. Wood screws
6. Two emergency override keys
7. One CD (software and manuals) |
Installation |
Non-professional, DIY. |